Inicio> Lista de Productos> Sensor actual> Sensor de corriente Fluxgate de alto precisón DXE100-210-G
Sensor de corriente Fluxgate de alto precisón DXE100-210-G
Sensor de corriente Fluxgate de alto precisón DXE100-210-G
Sensor de corriente Fluxgate de alto precisón DXE100-210-G
Sensor de corriente Fluxgate de alto precisón DXE100-210-G
Sensor de corriente Fluxgate de alto precisón DXE100-210-G

Sensor de corriente Fluxgate de alto precisón DXE100-210-G

$1≥100Piece/Pieces

Tipo de Pago:T/T
Incoterm:FOB,CFR,CIF,EXW,FCA
Cantidad de pedido mínima:100 Piece/Pieces
transporte:Ocean,Land,Express,Air
Hafen:SHANGHAI,NINGBO,GUANGZHOU
Atributos del producto

ModeloDXE100-210-G

MarcaDexie, el servicio OEM está disponible

Lugar De Origenporcelana

Accuracy100ppm

Embalaje y entrega
Unidades de venta : Piece/Pieces
Tipo de paquete : Cartones / paleta
Descargar :

The file is encrypted. Please fill in the following information to continue accessing it

Descripción

Sensor de corriente de puerta de flujo DXE100-210-GI PN = 100 A

El DXE100-210-G es un sensor de corriente de puerta de flujo avanzado que usa alta tecnología para traer la mejor combinación de rendimiento y confiabilidad. Se clasifica para un rango de medición de corriente primaria de ± 100A DC. Se calibra y se compensa la temperatura para mejorar la precisión utilizando la caracterización de la temperatura de múltiples puntos.


DIFERENCIACIÓN

● Precisión: caracterización de temperatura de múltiples puntos y calibración para una mayor precisión sobre el rango de temperatura.

● Inmunidad magnética: la configuración de la puerta de flujo y el circuito magnético optimizado permiten un excelente rendimiento en diversos entornos magnéticos.

● Flexible: firmware a bordo personalizable para cumplir con los requisitos específicos de la aplicación.


Características

● Excelente precisión

● Muy buena linealidad

● Drift a baja temperatura

● ancho de banda de frecuencia amplia

● Tiempo de respuesta optimizado


Aplicación Domai n

● Verificación metrológica y calibración

● Medición actual de laboratorio

● Instrumentación (por ejemplo, analizador de potencia)

● Equipo médico, como imágenes de resonancia magnética (MRI)

● Detección del paquete de baterías

● Control de energía


Datos eléctricos

Parameter

specifications

Condition

Minimum value

Standard value

Maximum value

Rated input current IPN=

 ±100 Adc

/

Measure range IPM=

 

±150 Adc

 1Min/Hour

Power supply voltage VC

±12 Vdc

±15 Vdc

Full range 

Current consumption IC

±20 mA 

±120 mA

±220 mA 

IPM  range

Current change KN

 1000:1 

Input : Output

Rated output current ISN

100 mA 

Rated input current

Measuring resistance RM

40Ω


Exactitud- Parámetro dinámico

Project

Symbol

Test conditions

Numerical value

Unit

minimum

standard

maximum

Accuracy

Xe

25±10

--

--

100

ppm

Ratio error

XGe

--

--

100

ppm

angle error

XPe

--

--

0.01

crad

Linearity

εL

--

--

--

100

ppm

Temperature drift coefficient

TCI

--

--

--

1

ppm/K

Time drift coefficient

TT

--

--

--

1

ppm/month

Power supply anti-interference

TV

--

--

--

1

ppm/V

Zero offset current

Io

25±10

--

--

0.01

mA

Zero offset current

IoT

Within the full operating temperature range

--

--

±0.01

mA

Ripple current

In

DC-10Hz

--

--

0.5

ppm

Dynamic response time

Tr

di/dt=100A/us

--

--

10

us

rise to 90% IPN

Current following speed

di/dt

--

100

--

--

A/us

Bandwidth(- 3 dB)

F

--

0

--

10

kHz


Características generales

Project

Symbol

Test conditions

Numerical value

Unit

minimum

standard

maximum

Operating temperature range

TA

--

-40

--

85

Storage Temperature Range

TS

--

-40

--

85

Weight

m

 

100g

g


Características de seguridad

Project

Symbol

Test conditions

Numerical value

Unit

minimum

standard

maximum

Withstand voltage

Between primary and secondary edges

Vd

50Hz,1min

 

3

 

KV

Transient isolation withstand voltage

Between primary and secondary edges

Vw

50us

 

5

 

KV


NOTA

● Cuando la dirección de la corriente de entrada IP es consistente con la dirección indicada por la flecha en el dibujo del contorno, la corriente de salida está en la dirección hacia adelante.

● Intente ubicar el conductor primario en el centro de la apertura de la sonda tanto como sea posible.

● El agujero de paso está hecho de material metálico, por lo que el cable de orificio de paso no puede ser un cable expuesto. El cable de agujeros de paso debe estar aislado.

● Este módulo es un sensor estándar, contáctenos para obtener aplicaciones especiales.

● Nos reservamos el derecho de modificar este manual del sensor sin previo aviso.

Inicio> Lista de Productos> Sensor actual> Sensor de corriente Fluxgate de alto precisón DXE100-210-G
  • Móvil:

    +8618668863822

  • Email:

    cb_dennis@163.com

  • Dirección:

    Shanghai, Shanghai China

  • Follow us:

Hoja informativa

Sign up for industry alerts, our latest news. thoughts, and insights from Shanghai Zhilong Electronic Technology Co.,Ltd.

Copyright © 2024 Todos los derechos reservados por Shanghai Zhilong Electronic Technology Co.,Ltd.
Realizar consulta
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Enviar