Sensor de corriente fluxgate de alta precisión DXE500-R6/51
$1≥100Piece/Pieces
Tipo de Pago: | T/T |
Incoterm: | FOB,CFR,CIF,EXW,FCA |
Cantidad de pedido mínima: | 100 Piece/Pieces |
transporte: | Ocean,Land,Air,Express |
Hafen: | SHANGHAI,NINGBO,GUANGZHOU |
$1≥100Piece/Pieces
Tipo de Pago: | T/T |
Incoterm: | FOB,CFR,CIF,EXW,FCA |
Cantidad de pedido mínima: | 100 Piece/Pieces |
transporte: | Ocean,Land,Air,Express |
Hafen: | SHANGHAI,NINGBO,GUANGZHOU |
Modelo: DXE500-R6/51
Marca: Dexie, el servicio OEM está disponible
Lugar De Origen: porcelana
Accuracy: 0.01%
Unidades de venta | : | Piece/Pieces |
Tipo de paquete | : | Cartones / paleta |
Descargar | : |
The file is encrypted. Please fill in the following information to continue accessing it
Sensor de corriente de puerta de flujo DXE500-R6/51 I PN = 500 A
DIFERENCIACIÓN
● Precisión: caracterización de temperatura de múltiples puntos y calibración para una mayor precisión sobre el rango de temperatura.
● Inmunidad magnética: la configuración de la puerta de flujo y el circuito magnético optimizado permiten un excelente rendimiento en diversos entornos magnéticos.
● Flexible: firmware a bordo personalizable para cumplir con los requisitos específicos de la aplicación.
Características
● Excelente precisión
● Muy buena linealidad
● Drift a baja temperatura
● ancho de banda de frecuencia amplia
● Tiempo de respuesta optimizado
Aplicación Domai n
● Verificación metrológica y calibración
● Medición actual de laboratorio
● Instrumentación (por ejemplo, analizador de potencia)
● Equipo médico (por ejemplo, MRI)
● Detección del paquete de baterías
● Control de energía
Datos eléctricos
Parameter |
specifications |
Condition |
||
Minimum value |
Standard value |
Maximum value |
||
Rated input current IPN= |
±500 Adc |
/ |
||
Measure range IPM= |
|
±600 Adc |
1Min/Hour |
|
Power supply voltage VC |
±14 Vdc |
±16 Vdc |
Full range |
|
Current consumption IC |
±30 mA |
±280 mA |
±330 mA |
IPM range |
Current change KN |
2000:1 |
Input : Output |
||
Rated output current ISN |
250 mA |
Rated input current |
||
Measuring resistance RM |
10Ω |
15Ω |
Exactitud- Parámetro dinámico
Project |
Symbol |
Test conditions |
Numerical value |
Unit |
||
minimum |
standard |
maximum |
||||
Accuracy |
Xe |
@0%~24%IPN |
-- |
-- |
0.012 |
A |
@24%IPN~IPM |
-- |
-- |
0.01 |
%RD |
||
Ratio error |
XGe |
@0%~24%IPN |
-- |
-- |
0.002 |
A |
@24%IPN~IPM |
-- |
-- |
0.012 |
%RD |
||
Angle error |
XPe |
|
-- |
-- |
0.01 |
crad |
Linearity |
εL |
-- |
-- |
-- |
50 |
ppm |
Temperature drift coefficient |
TCI |
-- |
-- |
-- |
2 |
ppm/K |
Time drift coefficient |
TT |
-- |
-- |
-- |
2 |
ppm/month |
Power supply anti-interference |
TV |
-- |
-- |
-- |
5 |
ppm/V |
Zero offset current |
Io |
25±10℃ |
-- |
-- |
±0.006 |
mA |
Zero offset current |
IoT |
Within the full operating temperature range |
-- |
-- |
±0.015 |
mA |
Ripple current |
In |
DC-10Hz |
-- |
-- |
2 |
ppm |
Dynamic response time |
Tr |
di/dt=100A/us |
-- |
-- |
1 |
us |
rise to 90% IPN |
||||||
Current following speed |
di/dt |
-- |
100 |
-- |
-- |
A/us |
Bandwidth(- 3 dB) |
F |
-- |
0 |
-- |
100 |
kHz |
Características generales
Project |
Symbol |
Test conditions |
Numerical value |
Unit |
||
minimum |
standard |
maximum |
||||
Operating temperature range |
TA |
-- |
-40 |
-- |
85 |
℃ |
Storage Temperature Range |
TS |
-- |
-45 |
-- |
85 |
℃ |
Weight |
m |
|
280g±30g |
g |
Características de seguridad
Project |
Symbol |
Test conditions |
Numerical value |
Unit |
|||
minimum |
standard |
maximum |
|||||
Withstand voltage |
Between primary and secondary edges |
Vd |
50Hz,1min |
|
3 |
|
KV |
Transient isolation withstand voltage |
Between primary and secondary edges |
Vw |
50us |
|
5 |
|
KV |
Características mecánicas
● Tolerancia general: ± 0.8 mm
● Conector: KF2EDGCV-X-5.08-4P (espacio de 5.08 mm)
NOTA
● Cuando la dirección de la corriente de entrada IP es consistente con la dirección indicada por la flecha en el dibujo del contorno, la corriente de salida está en la dirección hacia adelante.
● Intente ubicar el conductor primario en el centro de la apertura de la sonda tanto como sea posible.
● El agujero de paso está hecho de material metálico, por lo que el cable de orificio de paso no puede ser un cable expuesto. El cable de agujeros de paso debe estar aislado.
● Este módulo es un sensor estándar, contáctenos para obtener aplicaciones especiales.
● Nos reservamos el derecho de modificar este manual del sensor sin previo aviso.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.